✓ Received
✓ Strip & assess
✓ Machining
✓ Reassembly
Pressure test
Paint & dispatch
Dispatched
Parts — allocated from stores, issued on dispatch
| Code | Part | Bin | Qty | On hand | Cost | ||
|---|---|---|---|---|---|---|---|
| PLG-PUMP | Pump plunger — BRW630 | G-01 | 10 | 8 | $9,400.00 | Allocated | |
| VLV-PUMP | Pump suction/delivery valve kit — BRW630 | G-02 | 10 | 12 | $3,850.00 | Allocated | |
| FLT-PUMP | High-pressure filter element — 25 µm | G-03 | 4 | 9 | $872.00 | Allocated | |
HighPressure test
- Customer
- Narrabri Underground
- Job
- J-26-0194 Emulsion pump overhaul — 2 × BRW630/37.5
- Serial
- SN 43750
- Qty
- 2
- Bay
- Bay 3 — gearboxes
- Fitter
- Tane Ngata
- Received
- 20 Sep 2026
- Due
- 12 Oct 2026
- Value
- $59,000.00
Findings
Plungers scored, suction valves pitted. Crankcase oil Fe 140 ppm — main bearings checked OK.Test
Not tested yet.
Phoenix Underground Pty Ltd
69 Depot Road, Mudgee NSW 2850 · (02) 8074 4988 · admin@phoenixug.com.au
ABN 41 618 552 907
Test certificate
WS-26-0841
Received 20 Sep 2026
Dispatched —
Job J-26-0194
Customer
Narrabri Underground
Order 326868
| Component | Emulsion pump × 2 |
| Serial / cores | SN 43750 |
| Findings | Plungers scored, suction valves pitted. Crankcase oil Fe 140 ppm — main bearings checked OK. |
| Test | — |
| Result | Pending |
| Parts fitted | PLG-PUMP × 10, VLV-PUMP × 10, FLT-PUMP × 4 |
| Tested by | Tane Ngata · checked Brad Kelly, Workshop Manager |
Offsite & onsite overhauls · Longwall relocations · Condition monitoring · Engineering — NSW & QLD