Moranbah North Mine · condition monitoring
Anglo American · LW 211 · prepared by Phoenix Underground, Mudgee
Live · updated 01 Oct 2026 · 07:54
8units monitored
0in alarm
1on watch
01 Oct 2026 · 07:54latest reading
28 Nov 2026next change-out · MN-AFC-MG
Drives, shearer, pumps & mobile plantlatest reading per parameter
UnitLatest readingsHealthLife used · change-out
MN-AFC-MG
AFC maingate drive · Komatsu 1,000 kW planetary drive
Chain 1.12 % Sprocket 4.5 mm Fe 83 ppm Vib 8.5 mm/s Oil °C 72
● Watch
10,400 / 14,000 h Change-out 28 Nov 2026 · Vibration (overall velocity)
MN-AFC-TG
AFC tailgate drive · Komatsu 1,000 kW planetary drive
Chain 0.76 % Sprocket 3.6 mm Fe 61 ppm Vib 3.9 mm/s Oil °C 69
✓ OK
5,429 / 14,000 h Change-out 21 Dec 2027 · Run hours
MN-BSL-01
Beam stage loader drive · Komatsu 525 kW BSL drive
Chain 0.71 % Sprocket 3.2 mm Fe 51 ppm Vib 4.8 mm/s Oil °C 73
✓ OK
6,797 / 14,000 h Change-out 12 Oct 2027 · Run hours
MN-PS-01
Emulsion pump station 1 · Zhongmei (PSS) BRW630/37.5
Emulsion 4.6 % Pressure 340 bar Fe 106 ppm Vib 6 mm/s Oil °C 76
✓ OK
11,811 / 16,000 h Change-out 10 May 2027 · Run hours
MN-PS-02
Emulsion pump station 2 · Zhongmei (PSS) BRW630/37.5
Emulsion 5 % Pressure 363 bar Fe 45 ppm Vib 2.9 mm/s Oil °C 66
✓ OK
5,150 / 16,000 h Change-out 16 Apr 2028 · Run hours
MN-PS-03
Emulsion pump station 3 · Zhongmei (PSS) BRW630/37.5
Emulsion 4.8 % Pressure 354 bar Fe 64 ppm Vib 4 mm/s Oil °C 70
✓ OK
8,039 / 16,000 h Change-out 20 Nov 2027 · Run hours
MN-SHR-MG
Shearer ranging arm — maingate · Komatsu 7LS ranging arm
Fe 54 ppm Vib 3.2 mm/s Oil °C 67
✓ OK
3,015 / 9,000 h Change-out 10 Aug 2027 · Run hours
MN-SHR-TG
Shearer ranging arm — tailgate · Komatsu 7LS ranging arm
Fe 54 ppm Vib 3.5 mm/s Oil °C 68
✓ OK
3,273 / 9,000 h Change-out 28 Jul 2027 · Run hours
Forecast change-outsat 136 run-hours / week
UnitDriverHours leftChange-out
MN-AFC-MG AFC maingate drive Vibration (overall velocity) 3,600 28 Nov 2026
MN-PS-01 Emulsion pump station 1 Run hours 4,189 10 May 2027
MN-SHR-TG Shearer ranging arm — tailgate Run hours 5,727 28 Jul 2027
MN-SHR-MG Shearer ranging arm — maingate Run hours 5,985 10 Aug 2027
MN-BSL-01 Beam stage loader drive Run hours 7,203 12 Oct 2027
MN-PS-03 Emulsion pump station 3 Run hours 7,961 20 Nov 2027
MN-AFC-TG AFC tailgate drive Run hours 8,571 21 Dec 2027
MN-PS-02 Emulsion pump station 2 Run hours 10,850 16 Apr 2028
Recommendations1 open
MN-AFC-MG — AFC MG drive vibration rising 0.4 mm/s per week
Plan exchange overhaul before it reaches alarm.
CMA-1208 · raised 24 Sep 2026 · Quote with you
Phoenix UndergroundQuestions about a reading? Sophie Lindqvist, Condition Monitoring Lead · (02) 8074 4988 Limits: your site's agreed watch / alarm values. Change-outs forecast from run-hours and wear trend.
Built for Phoenix Underground by Praxa Tech · Custom build, owned by Phoenix Underground on final payment.